Technical data
PHOENIX 401 BASIC PULS forceArc
10 Item No.: 099-004838-PRA01
3 Technical data
3.1 PHOENIX 401 BASIC PULS forceArc
PHOENIX 401 PULSE forceArc
Setting range: Welding current / voltage
TIG
5 A / 10.2 V – 400 A / 26.0 V
MMA
5 A / 20.2 V – 400 A / 36.0 V
MIG/MAG
5 A / 14.3 V – 400 A / 34.0 V
Duty cycle at 20°C 40°C
60% DC
- A 400 A
80% DC
400 A - A
100% DC
370 A 360 A
Load alternation
10 min (60% DC
6 min welding, 4 min break)
Open circuit voltage
92 V
Mains voltage (tolerances)
3 x 400 V (-25% to +20%)
Frequency
50/60 Hz
Mains fuse (slow-blow safety fuse)
3 x 35 A
Mains connection lead
H07RN-F4G4
Max. connected power
21.5 kVA
Recommended generator rating
29.0 kVA
Cosϕ / efficiency
0.99 / 89%
Insulation class / protection classification
H / IP 23
Ambient temperature
-10°C to +40°C
Machine / torch cooling
Fan / gas or water
Cooling capacity at 1 l/min
1200 W
Max. flow rate
5 l/min
Max. initial coolant pressure
3.5 bar
Max. tank capacity
7 l
Coolant
Ex works: KF 23E (-10°C to +40°C) or
KF 37E (-20°C to +10°C)
Workpiece lead
70 mm
2
Dimensions L/W/H [mm]
1100 x 455 x 950
Weight
111.5 Kg
Constructed to standards
IEC 60974 / EN 60974 / VDE 0544
EN 50199 / VDE 0544 Part 206 /
/