EasyManua.ls Logo

Praxair PHOENIX 401 BASIC PULS forceArc - Choke Effect; Dynamics; Superpulses; Wire Burn-Back

Praxair PHOENIX 401 BASIC PULS forceArc
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functional characteristics
MIG/MAG welding
Item No.: 099-004838-PRA01 27
5.2.2.4 Choke effect / dynamics
Operating
element
Action Result Display
X x
Select dynamics welding parameter
Press until
DYN
LED “Dynamic” comes on.
-40 to +40
m/min
Dynamics setting on the rotary dial “Wire
speed/welding parameters”
-40 to +40
5.2.2.5 Superpulses
Operating
element
Action Result Display
X x
Selects super pulses
Press the “Select welding parameters” button
until “on/off Sup” appears on the display.
on/off Sup
m/min
Switches function on or off.
on/off Sup
Super-
puls
The signal light indicates when the function
has been activated.
5.2.2.6 Wire burn-back
Prevents fusing of the wire electrode in the molten pool.
Wire back-burn set too high: large drops developing on the wire electrode result in poor ignition
properties or the wire electrode sticking to the welding nozzle. Wire back-burn set too low: Wire
electrode sticks in the molten pool.
Operating
element
Action Result Display
3 sec.
Selects wire burn-back
m/min
Parameter setting
(setting range 0 to 499)

Table of Contents

Related product manuals