39
Only argument <0>, chromatic mode supported
1(default)-MaxNOP.
The MaxNOP value is a characteristic of the device and
can be read back by the IDE command.
In confocal mode, if less than NOP peaks are detected, all
thickness signals will be invalidated because peak
identification is not possible.
<Operation time in seconds, number
of powerups>
Query command, must contain the query arg.
First parameter 2: Operation time in seconds
First parameter 3: number of powerups
The fraction in % of the height of the smaller peak that
the signal must go below in order to separate 2 peaks.
Query full scale value in micrometers of the currently
selected probe.
0(default) - 7 (depending on the existence of the calibration
tables)
See also: SENX
<(probe index), SNr: (serial number
of probe), Range: (measuring
range)um>
Query details of SENsor (probe)
Without parameter: returns a string with serial number
and measuring range of the currently selected probe in
the following format:
(probe index), SNr: (serial number of probe), Range:
(measuring range)um
When used with enum as string parameter, the device
enumerates all available calibrated probes in one string,
separated by ;
See also: SEN
Set Factory Defaults
Without parameter: reset the normal operation
parameters.
With parameter: reset also the communication
parameters (IP).
The parameter set is NOT automatically stored in
nonvolatile memory. To do so, please issue the SSU
command!
x meaning the exact sample rate in
Hz in floating point format
Set measurement cycle frequency in HZ
30 - 4000(default)
See also: SRA
<0..17> <0..17> … <0..17> (max 16
times)
Set the content of the output telegram