Procedure 7.9- Replacing the Step-Up Pulley Assembly
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
1. Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower
PCA.
2. Remove the stairarm assemblies as described in Procedure 7.11, steps 2 to 4.
3. Remove the crankarm assemblies as described in Procedure 7.5, steps 2 to 5.
4. Remove tension from the input pulley and generator belts as described below:
a. Straighten the locking tabs and turn the left and right tension bolts counterclockwise until
tension is removed from both belts. (See Diagram 5.2)
b. Remove both tension bolts and slide the input belt off of the step up pulley assembly.
5. Place the input belt and step up belt in place on the replacement step up pulley. Set other
end of the generator belt on the generator pulley.
6. Replace the tension bolts and associated hardware removed in step 5b.
7. Tension both belts per Procedure 5.3. Note the differences between tensioning a new belt
and a existing (used) belt.
8. Replace the crankarms per Procedure 7.5, steps 6 to 10.
9. Replace the red battery lead removed in step 1 and check unit operation as described in
Section Four.
10. Replace the rear cover.

Table of Contents

Other manuals for Precor C524

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor C524 and is the answer not in the manual?

Precor C524 Specifications

General IconGeneral
BrandPrecor
ModelC524
CategoryFitness Equipment
LanguageEnglish

Related product manuals