Diagram 5
Loosening the bolts in the handrail clamps.
Upper handrail clamp
Ribbon cable
Upper column support
Cap
Console mounting plate
6. Remove the two bolts in the upper handrail clamp using the hex key provided
and place the handrail clamp within easy reach. Loosen, but do not remove,
the two bolts from the lower handrail clamp. See Diagram 5.
Diagram 6
Installing the reading rack.
Console mounting plate
Upper handrail clamp
Ribbon cable
Electronic console
7. Take the following steps to install the reading rack.
a. Position the reading rack over the upright support and electronic console
mounting plate. Thread the ribbon cable through the opening in the
reading rack. See Diagram 6.
b. Install the reading rack by aligning the two handrail clamp bolt holes on
the upright support and the two bolt holes on the console’s mounting
plate with the four holes on the reading rack. Refer to Diagram 6.
c. Reposition the upper handrail clamp over the reading rack so that the
clamp’s bolt holes align with the holes on the reading rack.
d. Hold the reading rack in place while you tighten the two upper handrail
clamp bolts using the 3/16" hex (F) key.
Upper column support
Reading rack