puller will be used to reinstall the cable through the inside of the handlebar post.
8. Remove the Data COMMcable from the inside of the handlebar post and right fork
weldment:
a. Attach a cable puller to the Data COMM cable LPCA connector.
b. Gently pull the cable (and attached cable puller) upward through the inside of
the right fork weldment (thru the lower and upper fork weldment cable access
holes) and out the top of the handlebar post weldment. Stop pulling when the
cable puller exits the top of the handlebar post weldment. Disconnect the cable
puller from the Data COMM cable leaving the cable puller inside the right fork
weldment.
IMPORTANT: Attach a cable puller (or fish tape) to the LPCA connector end of the
Data COMM cable before removing from the inside of the fork frame weldment. The
cable puller will be used to reinstall the cable through the frame.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 77
5 Replacement Procedures
Data COMM Cable Replacement

Table of Contents

Other manuals for Precor SPINNER CLIMB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor SPINNER CLIMB and is the answer not in the manual?

Precor SPINNER CLIMB Specifications

General IconGeneral
BrandPrecor
ModelSPINNER CLIMB
CategoryExercise Bike
LanguageEnglish

Related product manuals