100962 G PUBLICATION DATE 24 JUN 2008.DOC PROGRAMMING MANUAL 23
Select the preferred Language from the list by pressing the
ARROW LEFT or RIGHT button.
English is the default setting.
Press the ENTER button to confirm.
Insert the number of cycles at which a maintenance is
required. See Maintenance Manual.
the default setting is :
- 9999 for machines with top soap dispenser.
- 3000 for machines with front soap dispenser.
Press the ENTER button to confirm.
Insert the buzzer time. At the End of the Wash cycle, when
the message Unload is displayed, the buzzer will function for
the programmed time.
5 Seconds is the default value.
Press the ENTER button to confirm.
The buzzer will function each time the attention of the
operator is needed.
The programmable Buzzer time interval is not applicable in
the case of error messages.
With the Advance function you can Skip a Sequence or
extend & decrease the time of a Sequence.
Yes is the default value. (No for MB-machines)
Yes : the Advance function is enabled.
No : the Advance function is disabled.
Press the ENTER button to confirm.
To avoid mechanical temperature shock and to extend
the life time of your washing machine, after a hot wash, cold
water is injected bit by bit. As a result at the end of the hot
wash, the temperature will be lowered to about 65°C.
The automatic cool-down function will only be functional if a
hot wash with a temperature above 65°C has been
programmed and if a cold water inlet valve is programmed in
the next step. When a Cool-down sequence has been
programmed, the automatic cool-down will not function.
The automatic cool-down differs from a normal cool-down
sequence. The purpose of a cool-down sequence is to
En
g
lish
|
French
|
S
p
anish
|
German
|
Dutch
|
Czech
|
Polish
|
Finnish
|
Danish
|
Slovenian
|
Italian
|
I:Language
English
I:Service
Intervall : 9999
I:Buzzer
Time : 5 Sec
I:Allow
Advance : Yes
I:Automatic
Cooldown : Yes