100962 G PUBLICATION DATE 24 JUN 2008.DOC PROGRAMMING MANUAL 25
No : Temperature balance disabled.
Press the ENTER button to confirm.
For programming the ON-OFF reversing time at wash
speed, the default values are 12 Sec ON and 3 Sec OFF.
This corresponds with a normal wash action.
For a gentle wash action, it‘s recommended to program 3
Sec ON and 12 Sec OFF.
The purpose of these two items is to suggest the values to
avoid that the operator has to insert over and over again the
ON-OFF reversing times while programming new wash
programs.
Press the ENTER button to confirm.
FS120, MB90, MB140, MB180 : 12Sec ON and 5Sec OFF
By enabling the “Allow Display ECONOMIC” function : the
operator is requested to confirm for each wash program if the
program must function with an Economic water level.
When Economic has been selected at the start of the
cycle, the machine will function with 20% units less water
than the programmed value.
A minimum water level will always be respected to avoid that
the heating elements are heating without water.
No is the default value. NO is the suggested value.
Yes : Allow Display ECONOMIC enabled.
No : Allow Display ECONOMIC disabled.
Press the ENTER button to confirm.
The Full Control Computer controls the water temperature at
the water fill process. By programming the boiler temperature
an optimum process is obtained.
The Boiler temperature corresponds with the hot water supply.
60°C is the default value.
Make a selection between 50°C, 60°C, 70°C or 80°C.
Press the ENTER button to confirm.
It can occur that the temperature will raise above the
programmed value when the machine is heating very fast.
(Steam Heating) To avoid this, you can insert a percentage
at which the heating will be switched Off before reaching the
programmed temperature.
It takes some time before the hot and cold water is mixed
I:Boiler
temp.: 60°C
I:Motor On
Time : _ _ Sec
I:Motor Of
f
Time : _ _ Sec
I:Allow Display
ECONOMIC : No
I:Temp Overshoot
Protection: -00%