8611303 PROCUT45 PLASMA CUTTER V1.1
18 For technical questions call 1-800-665-8685
accidental injury could occur, if the power returns and
the unit is not switched off.
12. Make certain the power source conforms to requirements
of your equipment (see Specifications).
POWER TOOL PRECAUTIONS
This equipment requires a dedicated 230 volt, 28 amp single-
phase alternating current circuit equipped with a similarly rated
circuit breaker or slow blow fuse. Do not run other appliances,
lights, tools or equipment on the circuit while operating this
plasma cutting machine.
1. Do not drape or carry coiled welding cables on your body
when the cables are plugged into the plasma cutting
machine.
2. Do not start the tool when the electrode is touching the
workpiece.
3. Hold the tool by the insulated gripping surfaces when
performing an operation where it may contact hidden
wiring or its own cord and cables. Contact with a ‘live’ wire
will electrify exposed metal parts and shock the operator.
4. Take work breaks to prevent the tool's motor from
overheating and/or overloading. Refer to the plasma
cutting machines duty cycle in Specifications.
5. Keep hands away from the electrode and the area it is
being applied to when the tool is in operation.
6. Do not connect the plasma cutting machine ground clamp
to an electrical conduit. Do not weld on an electrical
conduit.
7. Do not touch the electrode or welded surface immediately
after use. The surface will be hot and may cause an injury.
8. Never use a tool with a cracked or worn electrode. Change
the electrode before using and discard the damaged one.