OPERATION
PERFORMER 980060 07/05/03
3-21
STAIR TOOL CLEANING
Stair Tool, Long, Part #78519
Stair Tool, Short, Part #78521
1. Set the temperature control to the desired
temperature setting. Slow engine speed down to
minimize excess heat.
2. Use one (1) "9502" spray tip in your stair tool.
FLOOD RESTORATION
Set the temperature to 50°F.
SHUTDOWN AND DAILY MAINTENANCE
1. Run fresh water through the chemical injection
system to flush out chemicals.
2. We recommend removing as much moisture from
your vacuum hoses as is reasonable. This will
prevent spillage of solution in your vehicle when
replacing hoses.
3. Position the throttle control to the first notch
(low speed).
4. Disconnect the vacuum hoses from the unit.
5. Set temperature dial to 50°F and allow the unit to
cool down to 180°F or less, and then close the
heat bypass valve completely. DO NOT over-
tighten the valve.
6. Pull the throttle all the way out to idle and allow
the unit to run for 1 minute in order to remove all
moisture from the vacuum pump.
NOTE: If finishing for the day: Push the throttle
all the way in, plug the vacuum inlets and spray
WD-40 (or equivalent) into the vacuum lubrication
cup (located at front of console) for 5 seconds.
This will lubricate the vacuum pump. Pull the
throttle back to idle and continue to step #7.
7. Turn the ignition switch to the OFF position.
8. Turn the water supply faucet off. Bleed the
pressure out of the water supply hose by
loosening the hose at the water supply. Unhook
the water supply hose and store in vehicle.
9. Relieve pressure from the cleaning tools and
pressure hoses by activating the valve on the
tools. Disconnect the tools and pressure hoses
from the unit and store all items.
10. Drain the waste tank and dispose of waste in a
proper manner.
NEVER dispose of waste in storm drains, water
ways, or on ground areas. Always dispose of
waste in accordance with Local, State, and
Federal laws.