Manual Profound VIBRA-series, version 2.00
30
The under Peak Type selected setting is also used for the VIBRA
+
function, described in paragraph 5.3.6.
In the PC software you can look up the applied category in the data under tab Saved traces. The chosen
category line in the Velocity/Frequency graph is also thicker than the other category lines.
The building category set for FFT/Method I cannot be changed in the VIBRA PC software. According to
FFT/Method I the system saves related to the chosen category the most relevant peak values per interval.
With Zero Crossing/Method II you are able to change the category in the PC software. Select the
Velocity/Frequency graph and choose Zero Crossing/Method II under Frequency of the Plot Settings.
Then you can select the desired category under Date/Time.
5.3.4 Code (VIBRA
+
-option)
The VIBRA processes the data in accordance with DIN 4150-3 June 2001.
The VIBRA-sbr does the same in accordance with the Dutch code SBR part A, B â 2002.
VIBRA
+
- users have the option to process the data in accordance to either DIN 4150-3 (and
simultaneously to DIN 4150-2) or to the Dutch code SBR Part A, and simultaneously to part B - 2002.
The default VIBRA
+
setting is DIN. To edit and change to SBR, enter the Code option and select with
the î-key SBR. Press OK.