Document # MAN0001 Issue 4.29 Page 25 of 34
External Reader Alarm Volume
Compatible external readers have a speaker that can be used for alarm sound. The volume of that
sound can be controlled using this engineers function.
The range of Values:
0 = Off
15 = Full Volume
Default Value:
15 = Full Volume
Related Engineers Menus:
31 Ext Reader Alarm Volume
External Reader Feedback Volume
Compatible external readers have a speaker that can be used for feedback sounds to the user. The
volume of that sound can be controlled using this engineers function.
0 = Off
15 = Full Volume
Default Value:
8 = Mid Volume
Related Engineers Menus:
32 Controller Feedback Volume
Status LED will Flash
Enter Engineer Password
* 1 2 3 4 5 6
Select Ext Reader Alarm Volume * 3 3
Status LED will stop Flashing
Complete & Exit Programming Mode
#
Enter selected value (0 to 15) 15
Status LED will Flash
Enter Engineer Password
* 1 2 3 4 5 6
Select Ext Reader Feedback Volume * 3 4
Status LED will stop Flashing
Complete & Exit Programming Mode
#
Enter selected value (0 to 15) 8