ProMinent
®
Technical data
Temperature details
CAUTION
The model 115 V may only be operated up to an ambient
temperature of 35 °C!
Otherwise, the pump may be damaged!
Storage and transport temperature: -10 °C...+50 °C
Function at ambient temperature: -10 °C...+45 °C
Admissible feed chemical temperature: -10 °C...+35 °C
Electrical data
Mains frequency: 50 Hz / 60 Hz
Material data
Model 230 V/AC CNPa
Nominal output: 11 W
Current I eff: 0.1 A
Peak current: 0.5 A
Switch-on peak current: < 4 A for < 0.1 ms
Fuse*: 0.16 AT
Model 115 V/AC CNPa
Nominal output: 11 W
Current I eff: 0.3 A
Peak current: 1.3 A
Switch-on peak current: < 3 A for < 0.1 ms
Fuse*: 0.315 AT
* Fuses must have approvals according to VDE, UL and CSA.
Material Long term at max. back max. 15 min.
feed unit pressure at max. 2 bar
PP 50 °C 100 °C
NP 45 °C 60 °C
PVDF 50 °C 120 °C
Liquid end Valves Gaskets Balls
PP PP EPDM Ceramic
PP PP FPM-B Ceramic
acrylic glass PVC FPM-B Ceramic
acrylic glass PVC EPDM Ceramic
PVDF PVDF PTFE Ceramic
Diaphragms: PTFE-coated
Housing: PPE, glass fibre reinforced
BA_CO_016_06_07_4spr.p65 21.06.2007, 12:48 Uhr26

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent CONCEPT PLUS Series and is the answer not in the manual?

ProMinent CONCEPT PLUS Series Specifications

General IconGeneral
BrandProMinent
ModelCONCEPT PLUS Series
CategoryWater Pump
LanguageEnglish

Related product manuals