26
ProMinent
®
Technical data
Temperature details
CAUTION
The model 115 V may only be operated up to an ambient
temperature of 35 °C!
Otherwise, the pump may be damaged!
Storage and transport temperature: -10 °C...+50 °C
Function at ambient temperature: -10 °C...+45 °C
Admissible feed chemical temperature: -10 °C...+35 °C
Electrical data
Mains frequency: 50 Hz / 60 Hz
Material data
Model 230 V/AC CNPa
Nominal output: 11 W
Current I eff: 0.1 A
Peak current: 0.5 A
Switch-on peak current: < 4 A for < 0.1 ms
Fuse*: 0.16 AT
Model 115 V/AC CNPa
Nominal output: 11 W
Current I eff: 0.3 A
Peak current: 1.3 A
Switch-on peak current: < 3 A for < 0.1 ms
Fuse*: 0.315 AT
* Fuses must have approvals according to VDE, UL and CSA.
Material Long term at max. back max. 15 min.
feed unit pressure at max. 2 bar
PP 50 °C 100 °C
NP 45 °C 60 °C
PVDF 50 °C 120 °C
Liquid end Valves Gaskets Balls
PP PP EPDM Ceramic
PP PP FPM-B Ceramic
acrylic glass PVC FPM-B Ceramic
acrylic glass PVC EPDM Ceramic
PVDF PVDF PTFE Ceramic
Diaphragms: PTFE-coated
Housing: PPE, glass fibre reinforced
BA_CO_016_06_07_4spr.p65 21.06.2007, 12:48 Uhr26