27
ProMinent
®
Technical data / Accessories
Climate
Admissible relative air humidity: 92 %, non condensing.
Load in wet and alternating climate: FW 24 in accordance with DIN 50016.
Enclosure rating and safety class
Contact and moisture protection: IP 65 in accordance with IEC 529,
EN 60529, DIN VDE 0470 Part 1 Safety class 1 - electric mains with earth
Technical data of inputs (contact input, level input)
Voltage at open contacts: 5 V DC ± 0.5 V
Input resistance: 12 kΩ ± 0.5 kΩ
Short-circuit current: 0.5 mA ± 0.05 mA
Maximum level for “0” signal: 1.0 V
Maximum level for “1” signal: 3.5 V
Minimum closing time contact input: 20 ms
Response time level input: 2 s
Sound pressure level
Sound pressure level: < 70 dB(A) at a distance of 1 m in accordance
with EN 23741 or EN 23742 at maximum stoke, maximum stroke rate,
maximum back pressure (water)
Shipping weight
Shipping weight: 1.8 kg
Suction lances
Retrofit kits
Suction lance for 200 l drum, tank opening 2“ DIN 570, PPE 1022511
Suction lance for 200 l drum, tank opening 2“ DIN 570, PCB 1022512
Suction lance for tank 5-50 l drum, tank opening d50, PPE 1022645
Suction lance for tank 5-50 l drum, tank opening d50, PCB 1022644
Adjustable suction lance with single-stage level switch, closing in the
event of lack of chemicals.
The delivery scope also includes the parts required for connecting the
pump.
Retrofit kit External + level CNP 1022099
Retrofit kit level switch CNP* 1022115
*connecting parts given suction lances and tanks provided by the
customer
11 Accessories
BA_CO_016_06_07_4spr.p65 21.06.2007, 12:48 Uhr27