Bonding the straight solvent union into a T-piece
Installing the sensor type ICT5 into PVC pipework. You can install the sensor into a PVC section
using the PVC straight solvent union supplied
Colour Material
Beige PP
Grey PVC
Use suitable adhesive, resistant to the media, for the materials to be bonded.
A2639
5
4
3
2
1
Fig. 8: Sensor and straight solvent union in a T-piece
1. Bond the straight solvent union (2) supplied into a standard T-piece (3) (on site).
When doing so, adhere to the minimum distances from the walls.