Manual & Installer Guide 60
Heat Pump Settings
Installation Settings
HP Lockout Outdoor Temp
(65˚)
Heat Pump will not run below this temp. (-20 - 75 deg. F)
Aux Heat Lockout - DISABLED
Aux Heat Lockout - ENABLED
Turns on Aux Heat Lockout.
Aux Heat Lockout Temp
(65˚)
Aux Heat will not run above this temp. (0 - 75 deg. F) GAS/EL or HP dip
switch must be set for HP and GAS or ELEC dip switch must be set for ELEC.
Heat Pump Lockout - DISABLED
Heat Pump Lockout - ENABLED
Turns on Heat Pump Lockout.
(Only available when
dip switch is set for
Heat Pump operation
AND you have a wired
outdoor temperature
sensor connected to
the thermostat)
(Continued)