75 Manual & Installer Guide
D. If you have a heat pump without aux heat, the ProStat+ model will require 5
wires: R (24Vac), C (24Vac), W1/O/B (Reversing Value), Y (1
st
Stage Compressor),
and G (Fan).
If you are short 1 wire, there are at least 3 options available to connect the
ProStat+ thermostat:
1. Use the available wires as instructed in the“Making 4 Wires
Work When 5 Wires Are Required” section on page 76 and note
that the fan will only operate with a Heating or Cooling demand.
2. Pull new thermostat wire from the HVAC equipment to the
thermostat so that there are at least 5 wires available.
3. Purchase and install a ProStat+ Add-A-Wire accessory.
E. If you have a heat pump with aux heat, the ProStat+ model will require 6 wires:
R (24Vac), C (24Vac), W1/O/B (Reversing Value), Y (1
st
Stage Compressor),
W2 (Aux Heat), and G (Fan).
If you are short 1 wire, there are at least 3 options available to connect the
ProStat+ thermostat:
1. Use the available wires as instructed in the“Making 5 Wires
Work When 6 Wires Are Required” section on page 77 and note
that the fan will only operate with a Heating or Cooling demand.
2. Pull new thermostat wire from the HVAC equipment to the
thermostat so that there are at least 6 wires available.
3. Purchase and install a ProStat+ Add-A-Wire accessory.
Installation Instructions – Wire Connections

Table of Contents

Other manuals for Prostat OEM Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Prostat OEM Series and is the answer not in the manual?

Prostat OEM Series Specifications

General IconGeneral
BrandProstat
ModelOEM Series
CategoryThermostat
LanguageEnglish

Related product manuals