6100 SINGLE LOOP DIGITAL
ADDRESSABLE FIRE ALARM
CONTROL PANEL
PC PROGRAM
MING MANUAL
2
Table of Contents
Default Chapter
3
Table of Contents
3
1 Important Notes - Please Read Carefully
5
2 Glossary of Terms
6
3 Introduction
8
4 Information Required Prior to Commissioning
9
Site Specific Information Required to Commission the 6100
9
5 Items Required to Commission the 6100 Using a Pc
9
PC / Laptop Requirements
9
Software and Hardware Requirements
9
6 Loading the 6100 Commissioning Software Onto a Pc
10
7 Connecting and Disconnecting the 6100 from the Pc
10
Connecting the PC to the 6100
11
Disconnecting the PC from the 6100
11
8 Overview of 6100 Commissioning Software Environment
12
The File Menu
13
The Edit Menu
13
The View Menu
14
The Panel Menu
14
The Help Menu
14
9 Creating a Site File
15
Creating a Blank Site File
15
Creating a Site File Using the Loop Commissioning Booklet
15
Creating a Site File by Logging and Mapping Devices Directly on the 6100
16
10 Programming Loop Device Data
16
Allocating a Zone Number to a Loop Input Device
16
Allocating an Input Group to a Loop Input Device
16
Allocating an Output Group to a Loop Output Device
16
Allocating an Output Group to the Conventional Alarm Outputs
16
Programming Loop Sounder Volume Levels
17
Allocating a Class to a Loop Device
17
Setting a Loop Input Device to be Latching or Non-Latching
17
Setting Automatic Detector Sensitivities
18
Programming Display Group Data
18
Programming Repeat Group Data
18
11 Programming Cause and Effect Sequences ( Matrix )
19
Setting up the Output Group Activation Tone
19
Setting up Output Group Delays
19
Programming the Output Group Type
20
Sound Alarms, Remote Alarm and Class Change Programming
20
Setting up Coincidence Operation
21
12 Entering Device, Zone and Panel Text
22
13 Programming Panel Configuration Data
23
Programming the Panel Access Codes
23
Programming the Global Fire and Fault Contact Operation
23
Programming the Fire Link Delay
24
Programming the Fire Link Search Time
24
Programming a First Knock Fire Link Delay Time
24
Programming the Walk Test Timeout
24
Programming Talking Sounder Options
25
Programming the Pulsing Alarm Timeout and Tone
25
Programming the System Pulsing Alarm Times
25
Programming Day and Night Sensitivity Times
26
Programming Remote Alarm Operation
26
Programming Class Change Operation
26
Programming Loop Beacon Operation
26
Overriding System Delays on a Second Knock Coincidence Activation
27
Pulsing the First Display Group into Alarm
27
Programming Loop Devices to 'Flash When Polled
27
Programming Dual Fire Link Outputs
27
14 Viewing Historic Event Logs
28
15 Uploading and Downloading Site Files to the 6100
28
Uploading a Site File from the 6100
28
Downloading a Site File to the 6100
28
Updating the 6100 Operating System
28
16 The Help Menu
28
Generating an Emergency Code ( Ecode )
28
Checking for Updates to the Commissioning Software
29
Downloading Online Documentation
29
Other manuals for Protec 6100
User Manual
34 pages
Installation And Commissioning Manual
52 pages
Need help?
Do you have a question about the Protec 6100 and is the answer not in the manual?
Ask a question
Protec 6100 Specifications
General
Frequency
50/60Hz
Batteries
2 x 12V 7Ah
Networking
RS485, Ethernet
Communication Protocol
Modbus
Certifications
EN54
Humidity Range
10% to 95% non-condensing
Related product manuals
Protec 3200
32 pages
Protec 3100
23 pages
Protec 3500
25 pages
Protec Digilite DL500
42 pages