INSSTCP0408
Ambient Mode (you only have to press down the A/F button to
switch from one mode to the other): this control method is ideal
when you want a stable ambient air temperature (without fluc-
tuation). Usually, this mode is used in large and often occupied
rooms where temperature variations can be uncomfortable. For
example, in a kitchen, a living room or a bedroom.
Some factors cause variations in ambient air temperature. They
include large windows (heat losses or gains due to outside tem-
perature) and other heat sources such as a central heating sys-
tem, a fireplace, etc. In all these cases, the Ambient mode will
ensure a uniform temperature.
This Thermostat is not Compatible with the Following
Installations:
•electricalcurrenthigherthan16Awitharesistiveload(3840W
@240VAC,3475W@208VACand1920W@120VAC);
•inductiveload(presenceofacontactororrelay);and
•centralheatingsystem.
Parts Supplied:
•one(1)thermostat;
•two(2)mountingscrews;
•four(4)solderlessconnectorssuitableforcopperwires;and
•one(1)oorsensor.
2. Installation
Selection of Thermostat and Sensor Location
The thermostat must be mounted on a connection box, at
around1.5m(5feet)abovetheoorlevel,onasectionofthe
wall exempt from pipes or air ducts.
Do not install the thermostat in a location where tempera-
ture measurements could be altered. For example:
•closetoawindow,onanexternalwall,orclosetoadoorlead-
ingoutside;
•exposeddirectlytothelightorheatoftheSun,alamp,are-