26 INS8800 Rev. D
Protimeter MMS2 Instruction Manual
9.2b Moisture Measurement
For Integrated and Remote Pin probes
Integrated pins
Strong and reliable integrated WME pins with cap,
No effect on readings by surface moisture
Pin (% WME) 8% to 100%, readings over 30% are relative
Non-invasive (RF)
Up to 3/4” (15 mm) deep, 60 to 999 (relative),
Tolerance: ±10 relative scale
9.2c Surface Temperature
Plug in Temperature Probe Surface Temperature Probe - BLD5805
Range 32°F to 158°F (0°C to 70°C)
Accuracy at 77°F (25°C) +/- 1.3°F (0.7°C)
IR Based — With 12:1 (D:S) Ratio — With Laser Pointer
Range: 14°F to 122°F (-10°C to 50°C)
Accuracy: ±3.6°F (±2°C) @77°F (25°C)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Protimeter MMS2 and is the answer not in the manual?

Protimeter MMS2 Specifications

General IconGeneral
Measurement ModesPin, Non-Invasive, Humidity, Temperature
Depth of Measurement (Non-Invasive)Up to 3/4 inch (19 mm)
Humidity Measurement Range0% to 100% RH
Temperature Measurement Range-4 to 140 °F (-20 to 60 °C)
Accuracy (Relative Humidity)±2% RH
Accuracy (Temperature)±0.5 °C