INS8800 Rev. D 25
Protimeter MMS2 Instruction Manual
9. Technical Specifications
9.1 Operating Conditions
Operating Temperature Range
Instrument Only: 0°C - 50°C
Humidity: 0 to 95% non-condensing
9.2 Measurement Specifications
9.2a Humidity Measurement
Hygrostick Data (Nominal)
Relative Humidity
Range: 30% to 40% RH, Accuracy: ±3% RH at 68°F (20°C)
Range: 41% to 98% RH, Accuracy: ±2% RH at 68°F (20°C)
Temperature
Range: 14°F to 122°F (-10°C to 50°C), Accuracy: ±0.6°F (±0.3°C)
Short Quikstick Data (Nominal)
Relative Humidity
Range: 0% to 10% RH, Accuracy: ±3% RH at 68°F (20°C)
Range: 10% to 90% RH, Accuracy: ±2% RH at 68°F (20°C)
Range: 90% to 100% RH, Accuracy: ±3% RH at 68°F (20°C)
Temperature Range
Range: 14°F to 122°F (-10°C to 50°C), Accuracy: ±0.6°F (±0.3°C)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Protimeter MMS2 and is the answer not in the manual?

Protimeter MMS2 Specifications

General IconGeneral
Measurement ModesPin, Non-Invasive, Humidity, Temperature
Depth of Measurement (Non-Invasive)Up to 3/4 inch (19 mm)
Humidity Measurement Range0% to 100% RH
Temperature Measurement Range-4 to 140 °F (-20 to 60 °C)
Accuracy (Relative Humidity)±2% RH
Accuracy (Temperature)±0.5 °C
DisplayLCD