Version 1.0
39
Troubleshooting
39
Condion Reason Acon Cause Correcon
No operaon
Braking coil burning
Measure brake phase resistance
value; change brake if value is
innite.
Excessive current caused by
high or low voltage
Operate under rated voltage
Avoid over-operaon
Excessive current caused by
overload
Operate under rated voltage
Conrm short-term rang,
intermient cycle rang,
operate under rated voltage
Excessive current caused
by operaon in singe phase
state
Stop immediately if unable to
li load in single phase
Fricon plate
beyond brake
magnesm scope
Measure brake clearance, replace
if space is over usage limit
Avoid over-operaon
Broken brake wire
Ensure wire is connected, replace
if disconnected
Lead wire damaged during
assembly
Replace coil brake
Improper
connecon of brake
wire terminal
Replace insert terminal when
loose
Assembly error Proper connecon in assembly
Rust Replace brake if rust present
Exposure to water in storage Ensure dry storage
Condensaon Monitor usage environments
Fricon plate wear
Measure brake clearance, replace
if space is over use limit
Avoid over-operaon
Brake
Inside Wiring
Condion Reason Acon Cause Correcon
No operaon
Break
Check cable, repair if wire break
Vibraon, drop
Avoid excessive bumping in
usage
Leading wire damaged in
assembly
Change motor coil
Check connector, repair if wire
break
Connector not properly set Press by appropriate tool
Wiring error
Refer to wiring diagram, ensure
properly connected
Wiring error
Refer to wiring diagram, ensure
properly connected
Connector screws
loose
Fastening
Improper fastening Ensure eecve fastening
(overheang) Vibraon, drop
Avoid excessive bumping in
usage
Connector, insert
terminal improper
combinaon
Proper combinaon
Bad combinaon during
assembly
Ensure combinaon is eecve