Troubleshooting
40
40
Condion Reason Acon Cause Correcon
No operaon
(contractor)
Coil burning, break
Measure coil resistance value;
Change transformer if value innite
Excessive voltage Operate under rated voltage
Avoid over-operaon
Excessive current caused by
contactor
Refer to contactor items
Vibraon, drop
Avoid excessive bumping in
usage
Wire break
Check leading wire, repair or
change transformer if wire
Vibraon, drop
Avoid excessive bumping in
usage
Transformer
Contactor & Electric Reply
Condion Reason Acon Cause Correcon
Non-stop acvaon
Juncon welding
burn out
Change contactor if connuous
welding or burn out. For electric
reply, visual inspecon of juncon
Do not over-operate
Excessive voltage (Excessive
current)
Operate under rated voltage
Excessive current due to
overload
Operaon under rated voltage
No operaon
Coil burning
Measure coil resistance value.
Change coil if value innite.
Avoid over-operaon
Excessive voltage Operate under rated voltage
Vibraon due to low voltage
(Starng current added
connuous)
Operate under rated voltage
Replace contactor if acon is not
smooth. For electric reply, visual
inspecon for part breakage
Vibraon, drop
Avoid excessive bumping in
usage