Setup Parameters / Functions
Setup parameters in the order displayed by the APEX access
device are:
RESTORE FACTORY
DEFAULTS?
Press * for YES
Press # for NO
This prompt only appears if the
program button is held while power is
applied to the APEX device. Pressing
the * key to select YES will restore all
of the factory defaults.
WARNING: This will overwrite all
setup parameters including the setup
password and the site name.
Restoring Defaults
Shown only while the APEX device is
restoring the factory defaults.
Defaults Restored!
Press # to Continue
Shown after the factory defaults are
restored.
Current Address: 001
Enter New Address:
PRESS # WHEN DONE
Polling address used by the controller.
Any number from 1 to 127 can be
entered. Each device connected to
the controller must have a unique
address. The factory default is 1.
The numbers 0 and 22 cannot be
used.
Communications Rate:9600
Press * to Change
PRESS # WHEN DONE
The communications baud rate used by
the controller. Scroll through the list of
available rates by pressing the * key. The
factory default is 9600.
APEX Access Device
33
rev. 7-2017 114A3863.E