EasyManuals Logo

Pyronix EURO 46 V10 Installation Manual

Pyronix EURO 46 V10
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
4
EURO 46 V10 Installation Manual
System Overview
System Overview EURO 46 V10 Additional Information
Areas
Independent areas 6
Wards 5 Each ward is created by a proximity reader
Inputs
On board 8 Supports N/C, 3EOL, DEOL and SEOL
Wireless 64 Requires 2 x EURO-ZEM32-WE
Maximum 76 Refer to ‘Input Mapping’ table
Outputs
PCB 5 1 Relay, 4 transistor (inputs 7 & 8 may be used as outputs)
AT E 10 Low power ATE outputs
Maximum 85 Refer to ‘Output Mapping’ table
User automation 30 Outputs programmed to activate on user command
Users
Users 75
Wireless key fobs 32 Requires 1 x EURO-ZEM32-WE
Guard/duress 10
Engineer 1
Maximum 87 Including Master Code and wireless key fobs
Arming Devices
Wired 6 Keypads and proximity readers
Wireless 4 Requires 1 x EURO-ZEM32-WE
Communication
Compatible modems PSTN, PSTN/VOICE, GSM, GPRS, Wi-Fi/XA and LAN
ARC formats Contact ID, Fast Format and SIA3 (also IP variants in all 3)
User formats Push notifications, SMS messaging and Voice messaging.
Phone numbers 10 Used for SMS messaging
UDL Support Ye s Using the upload/download software
Logs
Memory 1250 Memory type is EEPROM
Dimensions and Compliance
Dimensions
(H x W x D)
Small Case 297 x 250 x 82 mm
PCB 110 x 170 x 40 mm
Large Case 390 x 305 x 100 mm
EN grading 2 (small metal)
3 (large metal)
Environmental class II
Default Codes
Engineer - 1111
Master Manager - 2222

Other manuals for Pyronix EURO 46 V10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix EURO 46 V10 and is the answer not in the manual?

Pyronix EURO 46 V10 Specifications

General IconGeneral
BrandPyronix
ModelEURO 46 V10
CategorySecurity System
LanguageEnglish