EasyManua.ls Logo

QSC MP-M40 - Input Channel − Dynamics (Compressor; AGC); Compressor

QSC MP-M40
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
TD-001578-01-C
Input Channel − Dynamics
(Compressor / AGC)
The Input Channel Dynamics processing block may
be configured as either a Compressor or an Automatic
Gain Control (AGC).
Compressor
The Compressor controls the dynamic range of a signal
above a setThreshold.
1.
Dynamics
button – Selects the Compressor / AGC
screen.
2.
Compressor / AGC
button – Selects either
Compressor or AGC.
3.
In
switch – Engages and disengages the
Compressor or AGC processor.
4.
Knee In
button
Determines how
abruptly or gradually the
compressor transitions
in and out of gain
reduction as the threshold
iscrossed.
5.
Simple
button
Turns Simple mode on and off.
When on, it hides all controlsexcept:
Compressor / AGC
Comp In
Simple
Reset
Compression (Threshold)
All other controls remain at the value set prior to engaging the Simple mode button.
6.
Reset
button – Sets all the Compressor and AGC controls, for this channel, to their factory defaultposition.
7.
Input
meter – Displays the RMS input signal level.
8.
Reduction
meter – The red display indicates how much the signal is being reduced by the compressor. This meter displays a signal regardless
of whether the In button is engaged or not.
9.
Output
meter – Output level after any applied compression
10.
Compressor
graph – Vertical scale from 0 dB to -60 dB; horizontal measurement is time. When engaged, the trace displays.
Threshold
(A) – The level at which compression begins.
Attack
time (B to E) – The time it takes for the compression to reach its maximum compression after the input exceeds the thresholdlevel.
Ratio
(A to E) – The amount of compression applied to the signal.
Release
time (C to D) – The time it takes for the compressed signal to rise to the threshold level once the input level no longer exceeds
thethreshold.
11.
Threshold
slider – Sets the point at which the compressor begins to reduce signal level.
12.
Attack
slider – Adjusts how quickly the compressor reacts to a signal that exceeds the threshold.
13.
Release
slider – Adjusts how quickly the compressor stops compressing when signal falls below threshold.
14.
Ratio
slider – Sets the ratio of input level change to output level change when the signal exceeds the threshold.
15.
Gain
slider – Adjusts the overall output gain to makeup any loss after the signal is compressed.
16.
Compressor in/out
indicator – When the Compressor (or AGC) is In, an orange “
C
displays on the channel controls strip.
Inputs Touch an Input Bank
Touch a Channel
Dynamics Button
Mic/Line
(RCA / More)
B
E
C D A
3
4
1
15
10
9
6
8
11
5
16
12
13
14
2
7
Knee
In
Out

Table of Contents