13
TD-001578-01-C
Input Channel − Dynamics  
(Compressor / AGC)
The Input Channel Dynamics processing block may 
be configured as either a Compressor or an Automatic 
Gain Control (AGC).
Compressor
The Compressor controls the dynamic range of a signal 
above a setThreshold.
1. 
Dynamics 
button – Selects the Compressor / AGC 
screen.
2. 
Compressor / AGC 
button – Selects either 
Compressor or AGC.
3. 
In 
switch – Engages and disengages the 
Compressor or AGC processor. 
4. 
Knee In 
button
 
– 
Determines how 
abruptly or gradually the 
compressor transitions 
in and out of gain 
reduction as the threshold 
iscrossed. 
5. 
Simple 
button
 
– Turns Simple mode on and off. 
When on, it hides all controlsexcept:
•  Compressor / AGC 
•  Comp In
•  Simple
•  Reset
•  Compression (Threshold)
 All other controls remain at the value set prior to engaging the Simple mode button.
6. 
Reset 
button – Sets all the Compressor and AGC controls, for this channel, to their factory defaultposition.
7. 
Input 
meter – Displays the RMS input signal level.
8. 
Reduction 
meter – The red display indicates how much the signal is being reduced by the compressor. This meter displays a signal regardless 
of whether the In button is engaged or not.
9. 
Output 
meter – Output level after any applied compression
10. 
Compressor
 graph – Vertical scale from 0 dB to -60 dB; horizontal measurement is time. When engaged, the trace displays.
• 
Threshold
 (A) – The level at which compression begins.
• 
Attack
 time (B to E) – The time it takes for the compression to reach its maximum compression after the input exceeds the thresholdlevel.
• 
Ratio
 (A to E) – The amount of compression applied to the signal.
• 
Release
 time (C to D) – The time it takes for the compressed signal to rise to the threshold level once the input level no longer exceeds 
thethreshold.
11. 
Threshold
 slider – Sets the point at which the compressor begins to reduce signal level. 
12. 
Attack
 slider – Adjusts how quickly the compressor reacts to a signal that exceeds the threshold.
13. 
Release
 slider – Adjusts how quickly the compressor stops compressing when signal falls below threshold.
14. 
Ratio
 slider – Sets the ratio of input level change to output level change when the signal exceeds the threshold. 
15. 
Gain
 slider – Adjusts the overall output gain to makeup any loss after the signal is compressed.
16. 
Compressor in/out
 indicator – When the Compressor (or AGC) is In, an orange “
C
” displays on the channel controls strip.
Inputs Touch an Input Bank
Touch a Channel  
Dynamics Button
Mic/Line
(RCA / More)
 
B
E
C D A
3
4
15
10
9
6
8
11
5
16
12
13
14
2
7
Knee
In
Out