Menu − GPI Setup
The General Purpose Input (GPI) is used to recall Scenes
using a (hardware) switch connected to the rear panel of
the MP-M. There are two GPIs.
To use the GPI, at least one Scene must exist.
In the diagram, the condition of
GPI 1 is open, and the condition
of GPI 2 is closed.
1.
GPI 1 Open
(or GPI 2
Open) – Recalls the Scene
associated with the GPI
1 Open when the switch
attached to GPI 1 Open
isopened.
2.
GPI 1 Close
(or GPI 2
Close) – Recalls the Scene
associated with the GPI
1 Close when the switch
attached to GPI 1 Open isclosed.
3.
Action Name
The name of the Scene to be recalled
when the condition of open or close is satisfied.
4.
Disabled
/
Recall
switch – Enables or disables the
selected condition.
5.
Reset
– Resets the selected condition; no scene selected, and the Recall / Disabled switch to Disabled.
6.
Recall Scene
list – Displays the list of scenes created in the MP-M.
To Setup the Recall Conditions
a. Select one of the following: GPI 1 Open, GPI 1 Close, GPI 2 Open, or GPI 2 Close.
b. From the Recall Scene list, select a Scene to be recalled.
c. Set the Disabled / Recall switch to Recall.
Touch
Menu
Touch GPI
3
4
1
6
5
2
GPI-1 GPI-2