36
TD-001578-01-C
Mixer Main – PEQ
This screen controls and displays the settings for the Mixer 
Main Channel parametric equalization.
The PEQ is a 6-band, fully parametric EQ that includes 
variable High Shelf and Low Shelf Filters. Bands 1 and 6 
may be configured as shelvingfilters.
1. 
PEQ
 tab – Selects the EQ screen.
2. 
PEQ Out/In
 – Engages / disengages the equalizer.
3. 
RTA On
 – Engages / disengages the a real time 
analyzer that displays the tonal balance of the 
channel’s signal including peak hold indicators. 
NOTE: 
Only one 
RTA may be running 
on the system at a 
time. Touch the RTA 
button. If another 
device is using the 
RTA, the message shown above displays.
NOTE: 
When the RTA is off, the Parametric 
EQ graph expands to use the entire 
grapharea.
4. 
Simple 
button – Hides the Frequency, and Q controls for all bands. Changing to Simple mode does not affect existingsettings.
5. 
Reset 
button – Sets all the PEQ controls to their factory default position.
6. 
RTA 
display – Displays the amplitude of the channel signal in 1/3 octave bands. Peak hold indicators are displayed for each band.
• 
RTA
 graph vertical scale – Represents audio level from -60 dB to-5dB.
• 
RTA 
graph horizontal scale – Represents frequency from 31.5 Hz to 16 kHz.
7. 
Parametric EQ 
graph – A graphic representation of the equalization curve based on the PEQsettings. The trace dims to indicate that the PEQ 
is Out(disengaged).
• 
EQ 
graph vertical scale – Represents audio level from -20 dB to+20dB.
• 
EQ 
graph horizontal scale – Represents frequency from 20 Hz to 20 kHz.
8. 
EQ 
handles
 –
 Touch, hold, and drag to change the Frequency and Gain of the associated PEQ band. The frequency band button must be 
engaged to see the handles.
9. 
Low Shelf and High Shelf 
filter buttons – Changes EQ Band 1 and Band 6 from parametric filters to shelving filters. When a shelf filter is 
engaged, the Q control is not available. The low shelving filter raises or lowers a range of frequencies below the set frequency. The high shelving 
filter raises or lowers a range of frequencies above the set frequency. 
10. 
Frequency Bands 1, 2, 3, 4, 5, 6 
buttons – Engages / disengages the associated parametric EQ band. Each band is fully parametric with a 
frequency range of 20 Hz to 20 kHz.
11. 
Gain 
control knob and readout – Adjusts the gain at the frequency setting of the associated EQ band. Range of -15 dB to +15 dB.
12. 
Freq 
control knob (Frequency bands 1 – 6) – Sets the center frequency of the associated EQ band. If the Shelving filter is engaged, the Freq 
control sets the knee frequency of the shelf filter.
13. 
Q 
knob – Adjusts the Q of the associated EQ band. When the Shelf Filter is selected, the Q control is hidden. In addition, Q can be adjusted 
by“pinching”.
Touch 
Mixer
Touch Main 
Select
 
3 4
1
9
6
8
5
2
7
9
10
11
12
13
The RTA is currently being 
used by [device name]. Do 
you want to assign it in-
stead to this device?