Menu – System Test
The System Test screen is a setup and trouble-shooting
tool used to send test signals to the MP-M outputs.
1.
Source / RTA
a. When
Source
is selected, a screen is displayed
with options for selection of signal sources and
outputs to test.
b. When
RTA
is selected a Real Time Analyzer is
displayed.
2. Source
Input / Pink Noise / Sine Wave
a. Select
Source
>
Input
to use an Input as the test
signal source.
i. Select
Source
>
Input
>
Input
to choose the
MP-M Input to be used as a test signal source.
ii. Select
Source
>
Input
>
Gain
to adjust the
level of the Input test signal.
b. Select
Source
>
Pink Noise
to use Pink Noise as
the test signal source.
i. Select
Source
>
Pink Noise
>
Gain
to adjust
the level of the Pink Noise test signal.
c. Select
Source
>
Sine Wave
to use a Sine Wave
as the test signal.
i. Select
Source
>
Sine Wave
>
Frequency
to adjust the frequency of
the Sine Wave test signal.
ii. Select
Source
>
Sine Wave
>
Gain
to adjust the level of the test
signal.
3.
Select Output(s)
– Selects which output or outputs will receive the
testsignal.
4.
Enable
Toggles the test signal on and off.
5.
Meter
– Displays the output level of the source.
6. Select RTA –
a. Select
RTA
>
Inputs
– Select any input to view an RTA display of the
input’s pre-EQ signal.
b. Select
RTA
>
Outputs
– Select any output to view an RTA display of the
output’s post-EQ signal.
Touch
Menu
Touch
System Test
2.a.i
2.a.ii
1.a 1.b
4
5
2.a 2.b 2.c
3
2.b.i
4
5
2.a 2.b 2.c
2.c.i
2.c.ii
4
5
2.a 2.b 2.c
1.a 1.b
6.a
6.b