BMC SMASH
3-9
/SYS/voltage
This command returns a high level version of the system voltages health status.
*The sensor name list depends on the Server Hardware.
/SYS/fan
This command returns a high level version of the system fan health status.
*The sensor name list depends on the Server Hardware.
/SYS/temperature
This command returns a high level version of the system temperature health status.
Table 3.4: /SYS/voltage
PROPERTY NAME VALID VALUE ACCESS DESCRIPTION
Sensor name list of
vlotage
na
ok
nonCritical
critical
R
na
indicates the status not available /unknown
(typically because system power is off)
ok
indicates the monitored parameters within nor-
mal operating ranges
nonCritical
indicates the hardware outside normal operat-
ing range
critical
indicates the hardware exceeding specified rat-
ings
Table 3.5: /SYS/fan
PROPERTY NAME VALID VALUE ACCESS DESCRIPTION
Sensor name list of
fan
na
ok
nonCritical
critical
R
na
indicates the status not available /unknown
(typically because system power is off)
ok
indicates the monitored parameters within nor-
mal operating ranges
nonCritical
indicates the hardware outside normal operat-
ing range
critical
indicates the hardware exceeding specified rat-
ings

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the QUANTA QuantaGrid Series and is the answer not in the manual?

QUANTA QuantaGrid Series Specifications

General IconGeneral
BrandQUANTA
ModelQuantaGrid Series
CategoryServer
LanguageEnglish

Related product manuals