Chapter 11: System Specifications
DXi6900 Environmental Specifications
Quantum DXi6900 User’s Guide 394
SineVibration Operating Random 0.26 G’s, 5–350 Hz, Operational axis 10 minutes, psd:
0.0002 G2/Hz
Non-operating Random 0.5 G’s, 5–350 Hz, Operational axis 10 minutes, psd:
0.0007 G2/Hz
ShockVibration Operating 2 G’s for 11 ms, half-sine input, 3 shock pulses in both + and –
directions operational axis
Non-operating 3.5 G’s for 11 ms, half-sine input, 3 shock pulses in both + and –
directions operational axis
DXi6900Acoustic
Acousticoutput Operating Sound Pressure Level 72 dbA maximum at any operation position
DXi6900AgencyApprovals
EMC/Safety 47 CFR part 15 Class A
CNS 13438 Class A
CISPR 22 Class A
CISPR 24 Class A
EN 55022 Class A
EN 55024
EN 60590-1
EN 61000-3-2
EN 61000-3-3
IEC 60590-1
ICES-003 Class A
VCCI V-3/2011-04 Class A (DXi6900 G1)
VCCI V-3/2014-04 Class A (DXi6900 G2 / DXi6900-S)
AS/NZS 3548 Class A
KN22 Class A
KN24
UL 60590-1
ImmunityTests
Standards:
EN55024: 1998
+A1: 2001
+A2:2003
KN24
IEC 61000-4-2 (Ed. 2.0 2008-12) - Electrostatic Discharge (ESD)
IEC 61000-4-3 (Ed. 3.1 2008-04) - Radiated RF Immunity
IEC 61000-4-4 (Ed. 2.0 2004-07) - Electrical Fast Transient/Burst
IEC 61000-4-5 (Ed. 2.0 2005-11) - Surge Immunity
IEC 61000-4-6 (Ed. 2.2 2006-05) - Conducted RF Immunity
IEC 61000-4-8 (Ed. 1.1 2001-03) - Magnetic Field
IEC 61000-4-11 (Ed. 2.0 2004-03) - AC Dips and Interrupts