Parameter
Description
Conditions
Min.
Typ.
Max.
Unit
VBAT_RF
min/max values, including
voltage drop, ripple and
spikes.
Voltage drop during
transmitting burst
Maximum power control
level on GSM900.
400
mV
I
VBAT
Peak supply current
(during transmission
slot)
Maximum power control
level on GSM900.
1.8
2.0
A
USB_VBUS
USB detection
3.0
5.0
5.25
V
6.3. Operating Temperature
The operating temperature is listed in the following table.
Table 29: Operating Temperature
Parameter
Min.
Typ.
Max.
Unit
Normal Temperature
-35
25
75
ºC
Restricted Operation
-40 ~ -35
75 ~ 85
ºC
Storage Temperature
-45
90
ºC
6.4. Current Consumption
This information will be added in future version of this document.
6.5. RF Output Power
The following table shows the RF output power of EC25 module.