EasyManua.ls Logo

Quectel LC29H Series

Quectel LC29H Series
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GNSS Module Series
LC29H_Series_EVB_User_Guide 31 / 38
8.3. V_BCKP Power Consumption Measurement
Before measuring the V_BCKP power consumption, you must connect the components to EVB to ensure
that the module can communicate and fix normally. See Chapter 4.1 Testing via QGNSS.
Detailed steps for measuring V_BCKP power consumption with an ammeter:
Step 1: Switch off the power supply (S201) and pull out the V_BACK jumper cap (J202). Connect the
ammeter in series to both pins of J202, as shown below.
Step 2: Switch on the power supply (S201) and read the ammeter.
Ammeter
Figure 17: V_BCKP Power Consumption Measured with Ammeter
Detailed steps for measuring V_BCKP power consumption with a power consumption meter:
Step 1: Switch off the power supply (S201) and pull out the V_BACK jumper cap (J202). Then, ensure
the positive pole of the power consumption meter is connected to pin 1 (with arrow silkscreen) of
J202, and the negative pole is connected to GND.
Step 2: Switch on the power supply (S201) and read the power consumption meter.

Related product manuals