Q-41-MSII-2-EN 8.12 02-02-21
8.3 Error Messages (Malfunction Diagnostics)
The control system of the drive cyclically tests its own functional condition and the functional condition of
the complete drive system.
Malfunctions are signalled via the display of the external operator panel, for instance:
List of possible error codes:
11
11
1 Treadle not in zero position when mains power is turned ON
99
99
9 Start lock
1010
1010
10 Machine class, <799> was changed; remedy: turn mains power switch OFF and ON
again
6262
6262
62 Short circuit on 24 V (32 V) DC
6363
6363
63 Overload on 24 V (32 V) DC, load current > 4 amps
6464
6464
64 Power supply monitor: voltage too low (90 V - 150 V)
6565
6565
65 Power electronics not operational after mains power ON, mains power < 130 V
6666
6666
66 Earth short (motor or motor supply line has earth short in one or more phases)
6767
6767
67 Internal malfunction
6868
6868
68 Power electronics shut-off
a) Overcurrent, short circuit in motor or supply line
b) Overvoltage, mains voltage too high (>300 V), motor overloaded while decelerating
c) Undervoltage
7070
7070
70 Machine blocked, no increment from synchronizer at max. motor torque
7171
7171
71 Commutation transmitter plug not inserted
7373
7373
73 Motor overloaded
7575
7575
75 Internal malfunction
9090
9090
90 EEPROM does not exist
9191
9191
91 EEPROM not programmable
9292
9292
92 Start lock while motor running
9393
9393
93 Wrong EEPROM
100100
100100
100-
Internal malfunction
117117
117117
117
In case of error messages
≥ ≥
≥ ≥
≥ 62, the motor will stop in undefined positions.
Control system reset possible only by mains power OFF/ON.
ERROR 7 1