Q-41-MSII-2-EN 9.14 02-02-21
9.2.5 Reset
Any parameters having been modified from their original (standard) condition can be restored to their standard
condition by „reset“.
Exceptions:
Parameters 700, 799, 800 and some further parameters identified by „
4
“ in the list of parameters. For these
parameters, the conditions programmed by the user will be maintained even after a „reset“ is performed.
Reset Procedure
- Turn OFF power switch S1.
- Toe the treadle fully forward and hold in that position.
- Press and hold keys M- and V- simultaneously.
- Turn ON power switch S1.
- Stop pressing keys and stop toeing the treadle.
Response: Indication 6
To make „reset“, subsequently press key M+.
If it is intended not to make a „reset“, press key M-.
Subsequently, the display will show the indication 1.
TSE /-R
E
+
05 05
A