Function of the programming keys in operating mode ”parameter programming”
(key T9 is dark, key T10 is bright)
- P+/P- switch over of the hundreds of the parameter numbers
- S+/S- switch over of the parameter number in the switched on hundred section
- L+/L- programming of the parameter value of the switched on parameter number
Function of the keys T9 and T10 for selection of the operating mode
- T9 dark, T10 dark: manual sewing
- T9 bright, T10 dark: programmed sewing
- T9 dark, T10 bright: parameter programming
Function of the programming keys for machine functions
- T5 function change-over for keys T1T4 (shift key)
- T1 chain close-off (<425> = I)
- T5+T1 automatic change-over between program 1 and program 2 (see Item 8.2.2)
- T2 speed during programmed sewing:
variable (treadle-controlled) when T2 is dark or
constant (automatic) when T2 is bright
- T5+T2 no function
- T3 blow chain at seam end
- T5+T3 light barrier start
- T4 no function
- T5+T4 piece counter on display
- T6 vacuum at start of seam
- T7 vacuum at end of seam
- T8 currently no function
- T11 chopper at start of seam
- T12 chopper at end of seam
- T13 presser foot position at sewing stop
- T14 presser foot position at end of seam
- T15 light barrier
Caution: After programming push key T5 till LED goes out
The keys T1...T15 are provided with one signal lamp each (LED). Each LED provides optical feedback
on the control position of the function assigned to each key. If the function is ON, the LED is bright; if
the function is OFF, the LED is dark.