FinMDeploymentGuide Release4.5.10 424
ConfiguringtheCoChannelNeighborInterferenceMitigationOption ConfiguringtheRadioNetwork
IncolumnAV(CochannelNeighbors),recordthenameofthecochannelneighborTBS(s).
Iftherearetwocochannelneighbors,recordeachneighborsnameseparatedbya
comma(nospaces!),asshowninFigure 414:
Figure414:RecordingCoChannelNeighbors
TheIPaddress(es)ofthecochannelneighbor(s)appearautomaticallyincolumnAW.
Inourexample,thecochannelneighborofTBS1(BS.01.2.1)isBS.01.2.4,thatofTBS2
(BS.01.2.2)isBS.01.2.5,andofTBS3(BS.01.2.3)isBS.01.2.6.
StartingfromTBS4,eachTBShastwocochannelneighbors:theneighborsofTBS4
(BS.01.2.4)areTBS1(BS.01.2.1)andTBS7(BS.01.2.7),andsoon.
Thispatternwillrepeatitselfuntiltheendoftheline.ThelastthreeTBSsattheendofthe
line,likethefirstthree,willhaveonlyonecochannelneighbor.
14.CompleterecordingallofthecochannelneighborsforallTBSsinthespecificline
(w
ehaveonlyrecordeduptoTBS9inourexample).
15.IncolumnAY,recordtheCNIndex:ThisindicateswhichTBSwillusewhich
timeslotsintheframe‐thefirstpartorthesecondpart(seealsoFigure 411).
Record0fortheTBSsthatwillusethefirstpart,and1fo
rtheTBSthatwillusethe
secondpart.
Inourexample,TBS1,2,and3usethefirstpartofthe timeslotsintheframe(0is
recorded),whileTBS4,5,and6usethesecondpartofthetimeslots.ForTBS7,8,and9,
theyagainusethefirstpartofthetimeslots(so,forinstanceTBS4alwaysusesadifferent
partoftheframethanitscochannelneighbor:CNIndex1vs.CNIndex0forTBS1andfor
TBS7).Thepatternrepeatsitselfuntiltheendoftheline.