EasyManua.ls Logo

Ramsond CT Series - TROUBLESHOOTING; No Torch Arc or Inadequate Arc; O.C. (OVER CURRENT) Light is Lit

Default Icon
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R
amsond
Instruction Manual for CT 416 and 518 D & DX Series
© Copyright RAMSOND Corporation 2007 – All rights protected. Unauthorized reproduction, in part or whole prohibited.
®
TROUBLESHOOTING
SYMPTOM CAUSE / SOLUTION
No Torch Arc or Inadequate Arc
1. Incorrect Wiring - Check Main’s Wiring
2. Power Switch off -Turn Machine on
3. No main power
4. Inadequate Air Supply - Minimum 30 psi needed
5. Torch problem -change consumables and ensure proper
assembly.
6. Torch problem - There is short in the torch wire.
7. Cutting surface not grounded and connected to the
machine - make sure ground clamp is connected
8. Cutting surface is rusty - clean the rust
9. Lower the torch closer to cutting piece
O.C. (OVER CURRENT) Light is Lit
1. Duty Cycle reached - Wait a few moments until the
machine cools down.
2. Internal component problem. See professional assistance