Unit Installation cont
ELECTRICAL SUPPLY: Any wiring should be done by a qualified electrician in
accordance with local electrical codes. A properly wired and grounded outlet will
assure proper operation. Please consult the data tag attached to the compressor
to ascertain the correct electrical requirements. Supply voltage and amperage
requirements are located on the serial number tag located inside the mechanical
housing.
NOTE: It is important that a voltage reading be made at the compressor
motor electrical connections, while the unit is in operation to verify the
correct voltage required by the compressor is being supplied. Low or high
voltage can detrimentally affect operation and thereby void its warranty.
NOTE: it is important that your unit has its own dedicated line. Condensing
units are designed to operate with a voltage fluctuation of plus or minus 10%
of the voltage indicated on the unit data tag. Burn out of a condensing unit
due to exceeding voltage limits will void the warranty.