5.5 S3 Acceleration and deceleration ramp time
Set the acceleration and deceleration ramp time according to the table below.
It is not possible to separately set the acceleration and deceleration time.
For ControlMaster®NXT 003 , 1.5 s is the shortest possible ramp time.
Do not set the ramp time to be shorter than the original; this would shorten the lifetime of the
frequency converter. Increasing of the ramp time is allowed if the customer accepts it.
Table 9. Acceleration and deceleration ramp time
Ramp
time (s)
CMX 007 Switch S3 ControlMaster®NXT 003 Switch
S3
Ramp
time (s)
-1 -2 -3 -4 -1 -2 -3
0,5 1 1 1 1 1 1 0 1,5
1 0 1 1 0
1,5 1 0 0 0
2 0 1 0 0 0 1 1 2
2,5 0 0 0 0 0 1 0 2,5
3 0 0 1 0 1 0 1 3
3,5 0 0 0 1 0 0 0 3,5
4 1 0 0 1 1 0 0 4
4,5 1 1 0 0 0 0 1 4,5
5 0 0 1 1 1 1 1 5,5
5,5 1 1 1 0
6 1 1 0 1
6,5 1 0 1 1
7 1 0 1 0
7,5 0 1 1 1
8 0 1 0 1
R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319
23/28