4 OPERATING INSTRUCTIONS
4.1 Normal function
4.1.1 Control methods
Two speed joystick control
The motor moves at one of two preset speeds corresponding to the force applied to the direction control. The
motor moves at its slowest speed when the control is partially pushed and at its maximum speed when the control
is fully pushed. The motor stops moving when the joystick is released.
EP (Electronic Potentiometer) stepless pushbutton control
Released (stop):
The device doesn’t move or, if it is already moving, it will decelerate to a complete stop.
Fully pressed (accelerate):
The device accelerates continuously until the pushbutton
is released or the maximum speed is
reached.
Half-pressed (slow/hold):
If half-pressed the device will accelerate until it reaches the preset slow speed.
If half-pressed when the dev
ice is moving above the preset slow speed, the current speed will be
held without accelerating or decelerating.