NOTICE
All units are provided with BSP to garden hose
thread adapter(s) in starter kit.
article number: 50.00.790
NOTICE
The manufacturer recommends preventative
inspection be conducted around six months
after unit commissioning to ascertain the
degree of limescale buildup in the steam gen-
erator, especially for CMP/CM units.
This inspection should be performed by a
trained technician.
7.3 Water treatment
> The water connection must not use treated
water with hardness below 5.2 gr/gal, as
such water is aggressive and corrosive, and
can shorten the lifespan of the unit.
> Connecting the SCC to water with hardness
below 7.3 gr/gal:
When the self-test begins, the system will
prompt the user to indicate the hardness of
the water the unit is connected to. Select
“Water hardness below 7.3 gr/gal “treated
water”.
> Observe all country-specific regulations