- 25 - V02 en, SCC_WE
Interface PCB A1
X7 Power input to ON/OFF switch
X10 Central dial
X102 Touch
X150
X151
X152
X153 Data cable CPU (X107)
X154 Data cable TFT
X155
X158
Main PCB A2
X1 Pressure sensor P1 - 12V DC
X2 Thermocouple B3.1 - 3.6 core probe
X3 Thermocouple B1 cabinet
X4 Thermocouple B2 quenching
X5 Thermocouple B4 humidity
X6 Thermocouple B5 steam generator
X8 Loud speaker T2 - 12V AC
X11 Solenoid Y5 Clima - 12V DC
X12 Level electrode S2 - 12V AC 600Hz
X13 Cabinet light - 11.5V AC
X14 Power supply from transformer T1: - 11.5V AC, 18V AC
X15 CDS Sensor - 12V DC
X16
X18 SC Pump M4, Cleanjet Pump M6
X19 Solenoid Y1, Y2, Y3
X20 Energy optimising (Sicotronic) - link on 2-4
X21 230V Power input
X23 UltraVent without Bus (USA only)
X24 SSR - 12V DC
X25 Drain valve M7, Micro switch S12 - 12V DC
X26
X27 Door contact S3 - 12V DC
X29
X30
X51 Bus cable
X54 USB connection
X60 SD card slot
X75 cooling fan M5, Care Pump M12, Solenoid valve Y4
X106 Ethernet connection
X107 Data cable Interface PCB (X153)
F1 2A slow 230V power input X21
F2 2A slow 230V power input X21
LED Code CPU:
LED V10: Internal power supply 3,3V processor ok
if V10 off and V68 ok - change PCB
LED V68: 18V power supply from T1 ok
if V68 off - check connection, change transformer T1
SCC_WE CPU - Terminal connection - LED Code