Differences from SCC_WE (Index H) compared with SCC Index G
1. Unit self test after installation; all components are tested for correct function and determination of
boiling point;
2. Steam mode preset to boiling point (no hot air supply), 30-130°C possible (86 - 266°F)
3. New humidity control (Clima valve) for advanced dehumidification
4. New fan motor rotates left - right
5. New PCB and TFT touch display with Ethernet connection
6. Moistening nozzle integrated into hot air heating element flange of electric units
7. Modified cover for quenching box
8. Cooling fan is temperature controlled
9. Cleaning program „Light“ is split into „Light Quick“ duration approximately 1h 05min and
„Light standard“, duration approximately 1h 46min.
10. Operator and Application manuals are available on display;
Changes of the unit