- 37 - V02 en, SCC_WE
CareControl
The condition of the indication depends on:
a: the use of the unit
b: the cleaning behaviour of the customer
c: the degree of scale in the steam generator (see information
CDS).
Display Care
1: very good care - only one green bar visible.
2: medium care - yellow bars are visible
3: neglected care - red bars are visible
The request for Clean+Care has been neglected several times.
Only regular cleaning will reduce the display to one green bar again.
Display Clean
Actual dirt status
1: Only green bars visible - no cleaning necessary
2: Yellow bars visible - CleanJet request will show soon
3: red bars visible - Cleaning urgently required
CleanJet request is dependent on the usage pattern of the unit:
- SCC processes
- manual modes
- cooking programs
- duration
- temperatures
Using any of the Cleanjet programs: Quick, Save, Medium or Strong will reset the bars of the Display
Clean to 1 green bar (starting with software version 05-00-09).
CleanJet +Care can only be started when the cabinet temperature is below 50°C (122°F).