V02 en, SCC_WE - 46 -
Basic settings - Start
Training manual Gas
Basic Settings:
In Basic Settings all unit specific data
according to unit size, energy and
connections are set.
In order to store any changes made
the unit must be switched off and on
again.
Service Mode
Diagnostic
Basic Settings
Function Test
Calibration
Function key
Settings
HACCP
Communication
Service
Display Configurator
Gas: G20
RPM Correction 600m(ST) 500m(P1)
Ultravent: Yes / no
Gas blower settings:
Steam: Start Min Max
Hot Air top: Start Min Max
Hot Air bottom: Start Min Max
rpm 2500 1800 5800
default 2500 1800 5800
C0
2
screw: 4,8mm CO2 min: 8.7% CO2 max: 9.4%
rpm 4000 1900 6100
default 4000 1900 6100
C0
2
screw: 5,5mm CO2 min: 8.6% CO2 max: 9.4%
rpm
default
C0
2
screw:
Basic Settings
Water
General settings
Ultravent
Self test
Telefon
Gassystem
Actual service messages
Unit data empty
Steam generator
descaling (>16%)
Hotline Show mode
enter password
Q W E R T Z U I O P
A S D F G H J K L
Y X C V B N M
UK _+123 Äöüß