Drive Motor Control
Installation Instructions
8. Locate red power cable and place onto the red power
post, install M8 Flat Washer, Lock Washer and Hex
Nut and tighten with 13mm wrench (Fig. H).
9. Repeat Step 8 for black cable and black ground post.
10. Locate white plug and receptacle and reconnect (Fig. I).
11. Locate the (2) plugs under the large rubber boot
and
reconnect to their corresponding receptacles (Fig. J).
12. QC INSPECTION: Steps 8 - 11 must be checked
and
verified by Quality Control.
13. Place plugs back inside rubber boot.
M8 Nut, Flat
Washer &
Lock Washer
Red Power
Post
13mm
Wrench
Wiring
From DMC
H