25
8. CONTROL VALVE DELAY
Depress until DATA display flashes. The first digit, ( X 0 0 0 ), is the Control Valve delay digit.
This feature allows the user to set a delay between the time the booms are turned ON and when the
Console begins to control the flow rate. A value of 1-9 means a delay of 1-9 seconds respectively.
A value of 0 means no delay. This delay is active if the time between turning OFF and turning ON
the booms is less than 30 seconds.
11. ENTER MODE SEQUENCE WITH ACTIVATED DATA-LOCK
The DATA-LOCK feature prohibits the entry of data without first entering the DATA-LOCK CODE.
If DATA-LOCK is not desired, omit Steps 9, 10, and 11. The DATA-LOCK CODE may be cleared
by entering a code of "0" or by resetting Console.
1) Depress the key into which you wish to enter data.
2) Depress
, CODE message will appear. Enter your DATA-LOCK CODE. If CODE is correct,
"E" will appear. Now enter data normally.
To RESET Console: Place POWER ON/OFF switch to OFF, depress
and hold while
placing the POWER ON/OFF switch to ON.
10. SEQUENCE TO CHANGE DATA-LOCK
1) Depress for 5 seconds, OLD CODE message will appear.
2) Enter 4 digit code within 15 seconds
and .
NEW CODE message will appear. Enter 4 digit code within 15 seconds.
EXAMPLE: For 5821, depress
and .
9. SEQUENCE TO ACTIVATE DATA-LOCK
1) Depress for 5 seconds, NEW CODE message will appear.
2) Enter 4 digit code within 15 seconds.
EXAMPLE: For 0581, depress
and .