EasyManua.ls Logo

Raven SCS 661 - Control Valve Delay; Sequence to Activate Data-Lock; 10. Sequence to Change Data-Lock; 11. Enter Mode Sequence with Activated Data-Lock

Raven SCS 661
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
8. CONTROL VALVE DELAY
Depress until DATA display flashes. The first digit, ( X 0 0 0 ), is the Control Valve delay digit.
This feature allows the user to set a delay between the time the booms are turned ON and when the
Console begins to control the flow rate. A value of 1-9 means a delay of 1-9 seconds respectively.
A value of 0 means no delay. This delay is active if the time between turning OFF and turning ON
the booms is less than 30 seconds.
11. ENTER MODE SEQUENCE WITH ACTIVATED DATA-LOCK
The DATA-LOCK feature prohibits the entry of data without first entering the DATA-LOCK CODE.
If DATA-LOCK is not desired, omit Steps 9, 10, and 11. The DATA-LOCK CODE may be cleared
by entering a code of "0" or by resetting Console.
1) Depress the key into which you wish to enter data.
2) Depress
, CODE message will appear. Enter your DATA-LOCK CODE. If CODE is correct,
"E" will appear. Now enter data normally.
To RESET Console: Place POWER ON/OFF switch to OFF, depress
and hold while
placing the POWER ON/OFF switch to ON.
10. SEQUENCE TO CHANGE DATA-LOCK
1) Depress for 5 seconds, OLD CODE message will appear.
2) Enter 4 digit code within 15 seconds
and .
NEW CODE message will appear. Enter 4 digit code within 15 seconds.
EXAMPLE: For 5821, depress
and .
9. SEQUENCE TO ACTIVATE DATA-LOCK
1) Depress for 5 seconds, NEW CODE message will appear.
2) Enter 4 digit code within 15 seconds.
EXAMPLE: For 0581, depress
and .

Other manuals for Raven SCS 661