EasyManua.ls Logo

Raven SCS 661 - Scs 661 Communication Strings

Raven SCS 661
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
47
APPENDIX 8
SCS 661 COMMUNICATION STRINGS
REMOTE COMPUTER TO SCS 661 CONSOLE
All request strings begin with $R, to indicate a Raven communication string.
Rate 1 Change Request:
$R,RC,<rate_1_cal><CR><LF>
Calibration String Values Request:
$R,CR<CR><LF>
Data String Request:
$R,DR<CR><LF>
SCS 661 CONSOLE TO REMOTE COMPUTER
All console output strings begin with $R103*, the $R indicates a Raven communication string, the 103 is
the last three digits of the current SCS 661 programmed chip part number and "*" denotes the software
revision letter.
NOTE: The "*" will be a blank or a letter denoting revision level.
Calibration Strings:
$R103*,C1,<switch_byte_1>,<switch_byte_2>,<boom_1_cal>,
<boom_2_cal>,<boom_3_cal>,<boom_4_cal>,<boom_5_cal>,
<boom_6_cal>,<boom_7_cal>, <boom _8_cal>, <boom_9_cal>,
<boom_10_cal>, <speed_cal>, <CR><LF>
$R103*,C2,<meter_cal>,<spreader_constant><CR><LF>
$R103*,C3,<valve_cal>,<rate_1_cal>,<rate_2_cal><CR><LF>
Bit Switch Byte 1 Switch Byte 2
0 boom 1 boom 8
1 boom 2 boom 9
2 boom 3 boom 10
3 boom 4 rate 1
4 boom 5 rate 2
5 boom 6 0
6 boom 7 0
711
NOTE: If rate 1 and rate 2 are both zero, the console is in Manual. For switch Byte
Bits; 0 = off and 1 = on.
Data Strings:
$R103*,D1,<total_area>,<field_area><CR><LF>
$R103*,D2,<total_volume>,<field_volume><CR><LF
$R103*,D3,<tank_volume>,<distance><CR><LF>
Actual Rate:
$R103*,AR,<actual_rate><CR><LF>
Time/Date:
$R103*,TD,<hr:min>,<month/day/year>,<field_reference><CR><LF>