RG55 Operation • Service • Maintenance
800.392.2686
29
Operation
00-02-0839 - 4 - 2012-09-21
Main Menu
This section describes the items listed in the Main Menu. All interface with
the PV25 is through the Up/Down Arrows. When power is applied to the
unit, the Murphy logo displays first, and then the Parameter list begins to
display. The default display at start up is always the Parameter List.
Press both arrows simultaneously and then release to reach the Main
Menu. Use the Up and Down Arrows (buttons) to scroll through the items.
The Main Menu consists of Show 1-up, Active Faults, Stored Faults, Set
Units, Set 1-up, Scroll ON/OFF, Machine Hours ON/OFF, Tier 4 ON/OFF,
Set Tier 4, and Backlight. To return to the Parameter list, scroll to Show 1-
up and momentarily press both arrows, release and parameter readings
begin to display.
Menu
Item
Options Action
Show 1-
up
Switch to the parameter display. Momentarily hold the Up
& Down arrows, when
released, broadcast
parameters begin to
display.
Active
Faults
The Active Fault (Active FLTS)
menu shows the SPN (Suspect
Parameter Number), FMI (Failure
Mode Identifier), and OC
(Occurrence Count) for faults
currently broadcasting on the
CANBus.
When a new fault message is
received, the PV25 automatically
switches to Active Faults.
The Amber (left) or Red
(right) LED lights to
indicate the status of the
fault – Warning or
Shutdown.
If there is more than one
fault, the PV25
automatically scrolls
through each fault.
To return to the Main
Menu press the Up &
Down arrows
simultaneously and
release.

Table of Contents